Our Products

Hospital Evacuation Lift
- 18 People Can Be Rescued In One Go.
- 90% Faster Rescue Time.
- 99% Safer Than Available Solutions.
- 100% Friendly For Differently Abled.
- 120 Minutes Fire Rated Body.
- 2 Way Communication with PA System.
- Avoid Firemen Fatique
- Risk-Free Pathway
- Customized Cage Design
- Power Backup
- External Application
- Wireless Remote
- Customised As Per The Need
Frequently Ask Questions
What Is Fire Evacuation Lift ?
Fire Evacuation Lift” Purpose Is To Provide A Facility To Assist Fire-fighters To Move With More Ease Vertically Through A Building, And Rapid Evacuation Of Occupant In Fire Emergency In The Building Having Height 70 Meters And Above. Required Lift Access At Every Landing Or Mid-landing Of One Of The Enclosed Staircases Of The Building And The Said Staircase Shall Be Protected With Smoke Check Lobby By Means Of Fire Resistance Door Having 1 Hr. Fire Resistance, So Fire-fighter / Occupant Can Access The Lift Safely.
What Is Minimum Building Height To Put Fire Evacuation Lift?
As Per Govt. Advisory, Buildings With Height 70 Meters And Above Should Compulsorily Install Fire Evacuation Lift.
Can We Use Fire Evacuation Lift In Case Of Fire In Premises?
Fire Evacuation Lift Is Designed To Use For Building Evacuation In Case Of Fire. Lift Location Is Approved By Fire Department And It Is Protected By Smoke Check Lobby / Common Lobby With FRD.
Is License Mandatory In Case Of Fire Evacuation Lift?
Lift License Is Mandatory In Case Of Fire Evacuation Lift Same As Normal Passenger / Service Elevators. Entire Process To Obtain The License And List Of Documents Required By PWD Department Are Same As Normal Elevators.
Where Is Location Of Fire Evacuation Lift?
Locations Are As Below
Mid Landing (It Will Be Considered Only Post Fire Department & Energy Department Approved As Special Case If Building Is Constructed & Occupied Between January 2018 To July 2022)
A. Common Lobby With Fire Curtain / Common Lobby With FRD
B. Mid Landing With Smoke Check Lobby
C. Mid Landing Without Smoke Check Lobby
C Shaft With Fire Curtain / FRD
Can a goods lift within my existing premises be utilised/adapted to carry out Fire Evacuation lift function/provide compliance?
No. Generally speaking, to reduce the risk of the lift entrance being obstructed when the lift is required to operate on fire-fighters service, its use for moving refuse or goods should be restricted. Therefore, a lift whose primary intended function within the building is the regular movement of goods or refuse would be unsuitable.
Why cost of Fire Evacuation Lift is higher than Fire Lift?
Fire Evacuation Lift is having high level of safety standards compare to Fire Lift (like Cabin of Non-combustible metal with ceramic wool for 2-hrs fire rating, Fire rated vision panel doors, 30 Mins Jerk Less Back Up System, Fire Rated COP & LOP, FRLS Cables etc.) Fire Evacuation Lift is offering special features (like Fire Fighting apparatus, Exhaust Fan & Trap Door in Lift Cabin; 2-Way Intercom System on all floors; Provision for External Power Source; 2 no. Car Operating Panels; IOT based Automatic Notification to nearest Fire Brigade etc.) which are not available in normal Fire Lift. Fire Evacuation Lift should be working in case of Fire in premises against Fire Lift which is not used in case of fire. Due to this, we need to consider higher level safety factor compared to Fire Lift. Due to all these reasons, cost of Fire Evacuation Lift is on higher side compare to Fire Lift.
Can a goods lift within my existing premises be utilized/adapted to carry out Fire Evacuation lift function/provide compliance??
No. Generally speaking, to reduce the risk of the lift entrance being obstructed when the lift is required to operate on fire-fighters service, its use for moving refuse or goods should be restricted. Therefore, a lift whose primary intended function within the building is the regular movement of goods or refuse would be unsuitable.
Can This Elevator Accommodate In Existing Lift Shaft?
For Buildings With Existing Shaft, We Can Help With Customized Cabin Size To Accommodate. In Case, Lift Is In Common Lobby, Then As Per Guideline Received, Customer Need To Provide Fire Curtain / Fire Resistance Door And Also Obtain Necessary Approvals For Fire Evacuation Lift.
What Are The Additional Safeties Provided In Fire Evacuation Lift?
Following Additional Safety Features Are Provided In Fire Evacuation Lift Which Are Not Available In Passenger Lift / Fire Lift
- Cabin Panels Are Of Non-combustible Material Sandwich Panels With Ceramic Wool Of 2-hrs Fire Rating.
- Car Door And Landing Door With Vision Panel Glass And 2-hrs Fire Rating.
- 30 Mins Jerk Less Battery Back Up System
- Fire Fighting Apparatus In Lift Cabin Like Fire Extinguisher, First Aid Kit Etc.
- Fire Rated Cop & Lop
- Provision To Connect With External Power Source In Case Of Emergency
- IOT Based Controller With Automatic Notification To Fire Department
Spartan SFL © 2023 / ALL RIGHTS RESERVED